cbrn:RadInstrumentDataChoiceAbstract (abstract)
A data concept for a variant of data that is generated by the rad instrument.
Can be replaced with:
- cbrn:AnalysisResults
A collection of information resulting from an analysis of radiation measurements or derived data.
- cbrn:DerivedData
A set of all data derived from raw measured data for use in analysis.
- cbrn:EnergyCalibration
An energy calibration that spectrum measurements can reference as applicable to a particular spectrum.
- cbrn:EnergyWindows
A definition of a set of energy windows used in gross counting.
- cbrn:FullEnergyPeakEfficiencyCalibration
A full-energy peak efficiency calibration. The full-energy peak efficiency at any value of energy is the ratio of the net counts in a peak at that energy to the number of photons emitted by a source at that energy.
- cbrn:FWHMCalibration
A FWHM calibration for a gamma radiation detector; i.e., FWHM as a function of energy.
- cbrn:IntrinsicDoubleEscapePeakEfficiencyCalibration
An intrinsic double-escape peak efficiency calibration. The intrinsic double-escape peak efficiency at any value of energy is the ratio of the counts in the double-escape peak of that energy to the number of photons impinging on the radiation detector surface at that energy.
- cbrn:IntrinsicFullEnergyPeakEfficiencyCalibration
An intrinsic full-energy peak efficiency calibration. The intrinsic full-energy peak efficiency at any value of energy is the ratio of the net counts in a peak at that energy to the number of photons impinging on the radiation detector surface at that energy.
- cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration
An intrinsic single-escape peak efficiency calibration. The intrinsic single-escape peak efficiency at any value of energy is the ratio of the counts in the single-escape peak of that energy to the number of photons impinging on the radiation detector surface at that energy.
- cbrn:MultimediaData
A set of information about multimedia data - e.g., images, sound clips, movies, - regarding a measured item or a measurement environment.
- cbrn:RadMeasurement
A set of data for a radiation measurement at a particular StartDateTime, for a RealTimeDuration, of a particular MeasurementClassCode that consists of readings from any number of one or more of the following: - a radiation detector - an occupancy sensor - a positioning sensor that captures the location of a radiation measurement instrument, radiation detector, or measured item - the state of a radiation measurement instrument, radiation detector, or measured item
- cbrn:RadMeasurementGroup
A group of RadMeasurement elements.
- cbrn:TotalEfficiencyCalibration
A total efficiency calibration. The total efficiency at any value of energy is the ratio of the total recorded pulses in a spectrum to the number of photons emitted from a source at that energy.
- cbrn:RadInstrumentData (of cbrn:RadInstrumentDataType)
A set of all the measurement and analysis data reported by a radiation detection instrument, and all the reported information on the instrument, its radiation detector(s), and the item(s) it measured.