NIEM Wayfarer 5.1

Disclaimer: This tool was developed by Tom Carlson Consulting LLC. It was created from the official distribution of the data model. Tom Carlson Consulting LLC makes neither claim nor warranty that this tool provides an accurate representation of the NIEM data model. For official and authoritative representations, please visit the official NIEM release website. Non-English text Powered by Google Translate.


for

cbrn:DerivedData (cbrn:DerivedDataType)

A set of all data derived from raw measured data for use in analysis.

View UML for type: cbrn:DerivedDataType

cbrn:DerivedData is contained within these types:

cbrn:DerivedData can contain:
  • cbrn:MeasurementClassCode
        An indicator A code indicating whether the data are a measurement of an item (Foreground), an environmental background (Background), a calibration source (Calibration), the intrinsic activity of the radiation measurement instrument (IntrinsicActivity), or not specified (NotSpecified).
  • cbrn:StartDateTime
        A time corresponding to the start of the collection of the data contained in a particular measurement.
  • cbrn:RealTimeDuration
        A total clock time (in ISO 8601 format) expended by an instrument in collecting a measurement; the duration shall be greater than zero.
  • cbrn:Spectrum
        A single spectrum measurement with references to other pertinent information about the measurement.
  • cbrn:GrossCounts
        A gross count from a radiation detector.
  • cbrn:DoseRate
        A measured ambient dose equivalent rate, provided as a value and/or a qualitative description.
  • cbrn:TotalDoseNumeric
        A value for the accumulated ambient dose equivalent since the last radiation detection instrument reset, in microsieverts (Sv).
  • cbrn:ExposureRate
        A radiation exposure rate, provided as the measured value, and/or a qualitative description of an exposure rate level.
  • cbrn:TotalExposureNumeric
        A set of data for the accumulated exposure since the last instrument reset, in milliroentgen (mR).
cbrn:DerivedData can be contained in any of these elements:
  • Cannot be directly contained in anything
Everything cbrn:DerivedData can contain:
  • via cbrn:DerivedDataType
    • cbrn:MeasurementClassCode An indicator A code indicating whether the data are a measurement of an item (Foreground), an environmental background (Background), a calibration source (Calibration), the intrinsic activity of the radiation measurement instrument (IntrinsicActivity), or not specified (NotSpecified).
    • cbrn:StartDateTime A time corresponding to the start of the collection of the data contained in a particular measurement.
    • cbrn:RealTimeDuration A total clock time (in ISO 8601 format) expended by an instrument in collecting a measurement; the duration shall be greater than zero.
    • cbrn:Spectrum A single spectrum measurement with references to other pertinent information about the measurement.
    • cbrn:GrossCounts A gross count from a radiation detector.
    • cbrn:DoseRate A measured ambient dose equivalent rate, provided as a value and/or a qualitative description.
    • cbrn:TotalDoseNumeric A value for the accumulated ambient dose equivalent since the last radiation detection instrument reset, in microsieverts (Sv).
    • cbrn:ExposureRate A radiation exposure rate, provided as the measured value, and/or a qualitative description of an exposure rate level.
    • cbrn:TotalExposureNumeric A set of data for the accumulated exposure since the last instrument reset, in milliroentgen (mR).
  • via cbrn:RemarksComplexObjectType
    • cbrn:RemarkText A placeholder for comments intended to help the consumer of the data to understand better the information encapsulated by the parent element.
  • via structures:ObjectType
    • Nothing