NIEM Wayfarer 5.1

Disclaimer: This tool was developed by Tom Carlson Consulting LLC. It was created from the official distribution of the data model. Tom Carlson Consulting LLC makes neither claim nor warranty that this tool provides an accurate representation of the NIEM data model. For official and authoritative representations, please visit the official NIEM release website. Non-English text Powered by Google Translate.


for

cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration (cbrn:EfficiencyCalibrationType)

An intrinsic single-escape peak efficiency calibration. The intrinsic single-escape peak efficiency at any value of energy is the ratio of the counts in the single-escape peak of that energy to the number of photons impinging on the radiation detector surface at that energy.

View UML for type: cbrn:EfficiencyCalibrationType

cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration is contained within these types:

cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration can contain:
  • cbrn:EnergyValueList
        A list of energy values, in units of keV; the energies shall appear in the list in strictly increasing order. This element appears paired with an element that provides a corresponding list of other values, such as the EnergyDeviationValueList, FWHMValueList, or EfficiencyValueList elements. The number and order of corresponding values in the pair of lists must match.
  • cbrn:EfficiencyValueList
        A list of efficiency values as decimal fractions; i.e., normally between 0.0 and 1.0.
  • cbrn:EfficiencyUncertaintyValueList
        A list of the 1-sigma absolute uncertainties in a set of EfficiencyValueList.
  • cbrn:CalibrationDateTime
        A date and time at which a calibration was put into service.
cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration can be contained in any of these elements:
  • Cannot be directly contained in anything
Everything cbrn:IntrinsicSingleEscapePeakEfficiencyCalibration can contain:
  • via cbrn:EfficiencyCalibrationType
    • cbrn:EnergyValueList A list of energy values, in units of keV; the energies shall appear in the list in strictly increasing order. This element appears paired with an element that provides a corresponding list of other values, such as the EnergyDeviationValueList, FWHMValueList, or EfficiencyValueList elements. The number and order of corresponding values in the pair of lists must match.
    • cbrn:EfficiencyValueList A list of efficiency values as decimal fractions; i.e., normally between 0.0 and 1.0.
    • cbrn:EfficiencyUncertaintyValueList A list of the 1-sigma absolute uncertainties in a set of EfficiencyValueList.
    • cbrn:CalibrationDateTime A date and time at which a calibration was put into service.
  • via cbrn:RemarksComplexObjectType
    • cbrn:RemarkText A placeholder for comments intended to help the consumer of the data to understand better the information encapsulated by the parent element.
  • via structures:ObjectType
    • Nothing