Disclaimer: This tool was developed by Tom Carlson Consulting LLC. It was created from the official distribution of the data model. Tom Carlson Consulting LLC makes neither claim nor warranty that this tool provides an accurate representation of the NIEM data model. For official and authoritative representations, please visit the official NIEM release website.
A single spectrum measurement with references to other pertinent information about the measurement.
cbrn:Spectrum holds other objects.
cbrn:Spectrum can hold any of these following objects, starting with the most specific and becoming more generic as you move down the list:
A duration during which a detection assembly is sensitive to the input signal. The value of LiveTimeDuration is always less than or equal to the value of RealTimeDuration, because it does not include the time that the radiation detector was unable to re
Holds numbers.
A list of values, one for each of a spectrum's channels. The values represent the number of counts per channel.
Holds numbers.
An energy calibration that spectrum measurements can reference as applicable to a particular spectrum.
Holds other objects.
An intrinsic full-energy peak efficiency calibration. The intrinsic full-energy peak efficiency at any value of energy is the ratio of the net counts in a peak at that energy to the number of photons impinging on the radiation detector surface at that energy.
Holds other objects.
A full-energy peak efficiency calibration. The full-energy peak efficiency at any value of energy is the ratio of the net counts in a peak at that energy to the number of photons emitted by a source at that energy.
Holds other objects.
A FWHM calibration for a gamma radiation detector; i.e., FWHM as a function of energy.
Holds other objects.
An intrinsic single-escape peak efficiency calibration. The intrinsic single-escape peak efficiency at any value of energy is the ratio of the counts in the single-escape peak of that energy to the number of photons impinging on the radiation detector surface at that energy.
Holds other objects.
An intrinsic double-escape peak efficiency calibration. The intrinsic double-escape peak efficiency at any value of energy is the ratio of the counts in the double-escape peak of that energy to the number of photons impinging on the radiation detector surface at that energy.
Holds other objects.
A set of information regarding a radiation detector.
Holds other objects.
A total efficiency calibration. The total efficiency at any value of energy is the ratio of the total recorded pulses in a spectrum to the number of photons emitted from a source at that energy.
Holds other objects.
A Spectrum data element(s) used to produce derived data. There shall be no duplicate IDREF values in the list. This is required whenever the element is used within a DerivedData block, and is prohibited otherwise.
Holds other objects.
A placeholder for comments intended to help the consumer of the data to understand better the information encapsulated by the parent element.
Holds text.